1 MW Coolant Distribution Unit for Data Center Liquid Cooling

Cooling Solutions

By Joe Steele October 28, 2026

As AI and high-performance computing continue to increase data center heat loads, operators need cooling systems that can support demanding performance requirements. Liquid cooling is becoming an increasingly important part of data center infrastructure, with coolant distribution units (CDUs) playing a critical role in managing temperatures, coolant circulation, and heat transfer.

HydraCOOL by Supreme Integrated Technology (SIT) offers 1 MW coolant distribution units designed around the specific cooling requirements of each application. By integrating fluid management, pumping, heat transfer, filtration, and controls, SIT helps data center operators and cooling infrastructure providers develop coordinated liquid cooling solutions.

What Is a Coolant Distribution Unit (CDU)?

A coolant distribution unit manages coolant circulation and heat transfer within a data center liquid cooling system.

In a typical liquid-to-liquid CDU, two separate cooling loops work together:

  • Primary Loop (Facility Water System): Supplies cooling capacity from the facility’s cooling infrastructure.
  • Secondary Loop (Technology Cooling System): Circulates coolant through the IT equipment to absorb heat generated by servers and other computing components.

A heat exchanger transfers heat from the secondary loop to the primary loop without mixing the fluids. Pumps, valves, sensors, and controls help maintain the required flow, pressure, and coolant temperatures.

This arrangement allows the IT cooling loop to operate under conditions suited to the equipment while transferring heat to the facility’s cooling system.

HydraCOOL: 1 MW Coolant Distribution Unit Solutions by SIT

HydraCOOL by Supreme Integrated Technology (SIT) offers custom-engineered 1 MW CDU designed around the specific cooling requirements of each application.

Not every data center has the same cooling requirements. Facility layouts, equipment configurations, operating temperatures, available space, and control requirements can all influence CDU design.

HydraCOOL by SIT provides a custom approach to 1 MW cooling distribution units, bringing together the mechanical, hydraulic, electrical, and control functions needed for each application.

HydraCOOL coolant distribution units incorporate:

  • Pumping systems: Circulate coolant at the required flow and pressure.
  • Heat exchangers: Transfer heat between the IT and facility cooling loops.
  • Filtration: Help maintain coolant cleanliness and protect system components.
  • Valves and instrumentation: Support flow regulation, pressure monitoring, and temperature measurement.
  • Electrical controls and automation: Coordinate equipment operation, monitoring, alarms, and system interfaces.

By considering these components as part of one integrated solution, SIT can tailor the CDU configuration to the facility’s operating conditions and installation requirements.

What Should You Consider When Selecting a 1 MW CDU?

A CDU’s rated cooling capacity is only one part of the selection process. A 1 MW rating represents thermal cooling capacity under specified operating conditions. Actual performance depends on the data hall architecture, temperatures, flow rates, and other requirements of the connected system.

Several factors should be evaluated before selecting or designing a CDU.

Cooling Capacity and Temperature Requirements

The expected IT heat load, facility water temperature, and required coolant supply and return temperatures help determine the appropriate cooling configuration. 

Flow Rate and Pressure

The CDU must provide sufficient coolant flow while accounting for pressure losses through piping, manifolds, heat exchangers, and connected equipment.

Coolant Compatibility and Filtration

Coolant chemistry, material compatibility, and filtration requirements are important for protecting the Technology Cooling Loop.

Installation and Maintenance

Equipment footprint, piping connections, electrical requirements, and access to serviceable components can influence the final system layout. 

Why Choose a Custom CDU?

Standard CDU configurations may not accommodate every facility’s cooling requirements or physical constraints.

A custom CDU allows the system to be designed around the application rather than requiring the facility to adapt to a fixed equipment configuration.

For data center operators, this approach can help address:

  • Specific thermal requirements
  • Limited installation space
  • Existing facility connections
  • Electrical and control interfaces
  • Monitoring requirements
  • Maintenance and service access

SIT brings together fluid management, mechanical integration, electrical systems, and controls to develop a custom CDU configuration that aligns with the data hall architecture.

Frequently Asked Questions About 1 MW CDUs

What does a 1 MW CDU do?

A 1 MW coolant distribution unit is designed to manage the thermal load under specific operating conditions. It circulates coolant through the IT cooling loop and transfers heat to the facility cooling system through a heat exchanger.

How does a liquid-to-liquid CDU work?

A liquid-to-liquid CDU transfers heat between two separate cooling loops without mixing their fluids. Pumps circulate coolant through the IT loop, while a heat exchanger transfers the collected heat to the facility water system.

What determines a CDU’s cooling capacity?

Cooling capacity depends on coolant flow rate, temperature difference, fluid properties, heat exchanger performance, and the operating conditions of the connected cooling systems.

Can a custom CDU integrate with existing data center infrastructure?

Yes. A custom CDU can be designed around existing facility cooling connections, available electrical power, control interfaces, and installation constraints, provided the infrastructure can support the required operating conditions.

Data Center Cooling Solutions From SIT

Reliable data center liquid cooling requires more than individual components. Pumps, heat exchangers, filtration, controls, and facility interfaces must work together to support the required operating conditions.

HydraCOOL by SIT brings these elements together in a 1 MW coolant distribution unit designed around each application’s thermal, mechanical, and control requirements.

Planning a new data center or upgrading your liquid cooling infrastructure? Contact SIT to discuss a HydraCOOL CDU designed around your cooling capacity, flow requirements, controls, and facility layout.

news and insight

News and Insights

View Post
What Is a Coolant Distribution Unit (CDU)?
Cooling Solutions

1 MW Coolant Distribution Unit for Data Center Liquid Cooling

View Post
Hydraulic Systems

How to Properly Size a Hydraulic Actuator: 7 Factors to Consider

View Post
Marine & Offshore

How Shipyards Can Source Obsolete and Hard-to-Find Marine Parts